TROUBLESHOOTING
DISCONNECT POWER AT CIRCUIT BREAKER BEFORE SERVICING
PROBLEM POSSIBLE CAUSE(S) SOLUTION(S)
Water stays on: 1. All models - Check selector switch- Place selector switch in AUTO.
should be in AUTO.
2. All models - No blank space or yellow Be sure there is at least one blank space on
dial. Note that blank spaces provide off yellow dial between each watering zone.
operation.
Water stays off: 1. Power not applied to timer. Check circuit breaker to be sure breaker
panel has been turned back on. If in doubt,
check power at timer with volt meter.
2. Selector switch in OFF position. Place selector switch in either AUTO or ON.
3. Skipper wheel pins are not in OFF position Be sure skipper wheel pins are pulled up for
for operation. days which watering is desired.
4. Gold pin on yellow dial is not pressed Be sure gold pins on yellow dial are pushed
down for operation. down for operation at the desired times.
Does not change 1. Blank space has not been left on yellow Be sure at least one blank space is provided
zone: dial to allow valve to switch from one to on yellow dial when zone switching is
zone. desired.
Does not skip days: 1. Pin is not down on skipper wheel at Be sure to press pin or pins down for selected
proper day. days to skip watering.
2. Silver pin on yellow dial missing or not Be sure silver pin is located and pushed
pushed down. down on yellow dial.
TURN CIRCUIT BREAKER BACK ON AFTER SERVICING