MODEL: T1475BR
24 HOUR DIAL TIME SWITCH WITH ‘’SKIPPER ’’
FOUR POLE SINGLE THROW
40 AMP. INDUCTIVE TUNGSTEN OR 1000 V.A. PILOT DUTY EACH POLE 120V - 480V A.C.
40 AMP. TUNGSTEN EACH POLE 120V - 277 V A.C.
2 H.P. (24 FLA) - 120 V. AC; 5 H.P. (28 FLA) - 240 V. AC SINGLE PHASE
28 FLA 168 LRA (7 1/2 H.P. - 208V 10 H.P. - 240V 20 H.P. - 480V) THREE PHASE
®
INDEPENDENTLY WIRED CLOCK MOTOR: 480 VOLTS 60 HZ.
CLOCK MOTOR VOLTAGE AND CYCLE MUST BE AS SPECIFIED. TO
ORDER REPLACEMENT, INDICATE PART NO. (WG--) ON MOTOR COVER.
wire only with insulation to suit installation. See gauge selection table
for normal service applications. To make power connections see illus-
tration below. Replace front insulator before turning on electricity.
Motor voltage and cycle (Hz). must be as specified above.
PRESSURE PLATE
TERMINAL SCREW
MAKE SURE WIRE
INSULATION CLEARS
PRESSURE PLATE
MINIMUM
COPPER
WIRE SIZE
(AWG)
MAX.
LOAD
(AMP)
MIN.
INSUL-
ATION
TEMP(°C)
75°C INSULATION MAX. MOTOR
LOAD (HP)
SINGLE PHASE
3 PHASE
120 V. 240 V. 208 V.
240 V.
14
12
10
8
15
20
30
40
60
60
60
75
1/2
1
2
-
2
2 1/2
3
5
3
5
71/2
10
3
4
5
7/12
PROGRAMMING INSTRUCTIONS
OPERATING INSTRUCTIONS
TO SET “ON” AND “OFF” TIMES: Hold trippers against edge of CLOCK-
DIAL, pointing to time (AM or PM) when ON and OFF operations are desired,
tighten tripper screws firmly. See caution below. For additional tripper pairs
on CLOCK-DIAL order 156T1948A.
TO SET TIME-OF-DAY: Pull CLOCK-DIAL outward. Turn in either direction
and align the exact time-of-day on the CLOCK-DIAL (the time now, when
switch is being put into operation) TO TIME POINTER. DO NOT MOVE THE
POINTER.
TO SKIP OPERATION(S) ON SELECTED DAY(S): Insert SKIPPING SCREW(S)
in SKIPPER WHEEL for day(s) automatic operation(s) is/are NOT required.
Tighten screws firmly. Move MANUAL LEVER to “OFF” and rotate SKIPPER
TO OPERATE SWITCH MANUALLY: Move MANUAL LEVER bellow CLOCK-
DIAL left or right as indicated by arrows. This will not effect next operation.
CAUTION: TO AVOID SLOW TRIPPER ACTION FAILURE, DO NOT OPERATE
SWITCH MANUALLY NOR PLACE A TRIPPER 4 HOURS PRIOR TO ON/OFF
CUTOUT TRIPPER SWITCHING.
IN CASE OF POWER FAILURE, reset CLOCK-DIAL to proper time-of-day.
See programming instructions.
INTERMATIC INCORPORATED
SPRING GROVE, ILLINOIS 60081-9698
154--01609
TIME
POINTER
TIME
DIAL
OFF
TRIPPER
MANUAL
LEVER
SKIPPING
SCREW
SKIPPER
WHEEL
DAY
ARROW
ON/CUTOUT
TRIPPER
WIRING INSTRUCTIONS:
To wire switch follow diagram above.
Use solid or stranded COPPER
LR3730
(4PST)
WIRING DIAGRAM
480 V
60 HZ
TO
LOADS
SUPPLY
GROUND
SCREW
CLOCK
MOTOR
A
7
B
5
6
1
2
8
3
4